ورود به سایت

در سایت حساب کاربری ندارید؟ ثبت نام در سایت (به زودی!)

ثبت نام

دانلود انواع مقالات آی اس آی

دسته بندی مقالات

با عضویت در سایت مقاله یاب از تخفیف ویژه بهرمند شوید! عضويت (به زودی!)
تاریخ امروز
سه شنبه, ۲۵ دی

مدل سیال قطبی ناپایدار از جریان خون از طریق گرفتگی مخروطی X-شکل عروق : اثر کاتتر و سرعت لغزش

Unsteady polar fluid model of blood flow through tapered x-shape stenosed artery: Effects of catheter and velocity slip

نویسندگان

این بخش تنها برای اعضا قابل مشاهده است

ورودعضویت
اطلاعات مجله Ain Shams Engineering
سال انتشار 2015
فرمت فایل PDF
کد مقاله 19191

پس از پرداخت آنلاین، فوراً لینک دانلود مقاله به شما نمایش داده می شود.

اضافه‌کردن به سبدخرید

چکیده (انگلیسی):

In this paper, we considered the pulsatile flow of blood through catheterized tapered artery in the presence of an x-shaped stenosis. Blood flow is modelled as homogeneous incompressible couple stress fluid. Further the effects of velocity slip at the arterial wall are also examined. The analysis is carried out analytically and closed form solutions are obtained with the assumption of mild stenosis. In the present study, we analyze the effects of various fluid and geometric parameters on the physiological parameters such as resistance to flow and shear stress at the wall. The variation in the resistance to the flow and wall shear stress with respect to stenosis size (є; φ ), radius of the catheter (Rc), couple stress fluid parameters (β;ω), Reynolds number (Re) and pulsatile parameter (σ) has been studied. In particular shear stress at the wall is reckoned at both the locations corresponding to the maximum height of the stenosis. It has been observed that this physiological parameter is independent of the location of the maximum height in case of nontapered artery while these locations significantly impact the shear stress at the wall in case of tapered artery. The locations of the critical and maximum heights with corresponding annular radii are summarized in the form of Table 1. We also focussed our attention on the analysis of the wall shear stress over the entire stenosis region for various values of the geometric and fluid parameters. It is observed that the impedance and wall shear stress are increasing with increase in the radius of catheter and stenosis size while they are decreasing as the tapered parameter and the couple stress fluid parameters are increasing. It is observed that slip velocity and diverging tapered artery facilitate the fluid flow.

کلمات کلیدی مقاله (فارسی):

سیال جفت تنشی؛ جریان خون؛ عروق مخروطی؛ کاتتر؛ سرعت لغزش

کلمات کلیدی مقاله (انگلیسی):

Couple stress fluid; Blood flow; Tapered artery; Catheter; Slip velocity

پس از پرداخت آنلاین، فوراً لینک دانلود مقاله به شما نمایش داده می شود.

اضافه‌کردن به سبدخرید
کلیه حقوق مادی و معنوی برای ایران مقاله محفوظ است
در حال بارگذاری