ورود به سایت

در سایت حساب کاربری ندارید؟ ثبت نام در سایت (به زودی!)

ثبت نام

دانلود انواع مقالات آی اس آی

دسته بندی مقالات

با عضویت در سایت مقاله یاب از تخفیف ویژه بهرمند شوید! عضويت (به زودی!)
تاریخ امروز
پنج شنبه, ۴ بهمن

آمار ازمون ۶ دقیقه پیاده روی روی تریدمیل با استفاده از شتابسنج کلیدی mywellness

A quantification of the treadmill 6-min walk test using the MyWellness Key accelerometer

نویسندگان

این بخش تنها برای اعضا قابل مشاهده است

ورودعضویت
اطلاعات مجله journal of sport and health science 4 2015
سال انتشار Received 12 March 2013; revised 17 June 2013; accepted 2 September 2013 Available online 23 January 2014
فرمت فایل PDF
کد مقاله 753

پس از پرداخت آنلاین، فوراً لینک دانلود مقاله به شما نمایش داده می شود.

اضافه‌کردن به سبدخرید

چکیده (انگلیسی):

Background: Accelerometers have been suggested to provide additional information during the 6-min walk test which may be useful in evaluating changes in functional exercise capacity. The aim of the study was to identify whether the additional information measured by the MyWellness Key (MWK) accelerometer during a treadmill 6-min walk test (t-6MWT) was related to currently used outcome measures. Methods: Fifteen participants (9 males, 6 females) performed a self-paced t-6MWT. Respiratory gas analysis and walking distance were measured whilst wearing the MWK. Results: A significant correlation was established between activity counts and 6-min walk distance (6MWD) (r ¼ 0.847, p < 0.001) yet not 6-min walk work (6MWW) (r ¼ 0.337, p ¼ 0.220). Energy expenditure estimated by the MWK was strongly correlated to 6MWW (r ¼ 0.938, p < 0.001) but not 6MWD (r ¼ 0.477, p ¼ 0.072). The MWK significantly underestimated energy expenditure (36.73, CI ¼ 33.9e39.7 kcal) compared to gas analysis (54.35, CI ¼ 46.2e61.4 kcal) demonstrating poor agreement between the two analyses (Bias ¼ 17.61 kcal, Limits of agreement ¼ 37.4, þ2.2 kcal). Measurement of time spent undertaking light, moderate, and vigorous physical activity was not significantly different ( p > 0.05) between the MWK and gas analysis. Conclusion: Estimated energy expenditure provided by the MWK was strongly correlated to 6MWW; however, MWK underestimated energy expenditure as measured by gas analysis. The MWK may provide outcome data that supplement those currently provided by the 6MWD for functional capacity assessment during the t-6MWT. Co

کلمات کلیدی مقاله (فارسی):

6mwd، شتاب سنجی، ارزیابی فعالیت پزشکی، تناسب فیزیکی، تریدمیل 6MWT.

کلمات کلیدی مقاله (انگلیسی):

6MWD; Accelerometry; Physical activity assessment; Physical fitness; Treadmill 6MWT

پس از پرداخت آنلاین، فوراً لینک دانلود مقاله به شما نمایش داده می شود.

اضافه‌کردن به سبدخرید
کلیه حقوق مادی و معنوی برای ایران مقاله محفوظ است
در حال بارگذاری